Abstract:   (2519 Views)
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse sequence to the magnetic resonance imaging (MRI) scanner. CEST MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. This effect leads to a reduction in magnetic moments of water causing a corresponding decrease in the gray scale intensity of the image, providing a negative contrast in the CEST image. The CEST effect is complex, and it depends on the CEST agent concentration, exchange rates, the characteristic of the magnetization transfer (MT), and the relaxation properties of the tissue. The CEST contrast is different from the inherent MT of macromolecule bounded protons which evidently occurs as a dipole-dipole interaction between water and macromolecular components. Recently it was shown that CEST agents can be strongly affected by the MT and direct saturation effects, so corrections are needed to derive accurate estimates of CEST contrast. Specifically, the existence of an analytical relation between the chemical exchange rate and physiological parameters such as the core temperature, glucose level, and PH has generated more interest in quantification of the CEST contrast. The most important model was obtained by analyzing water saturation spectrum named magnetization transfer ratio spectrum that was quantified by solving Bloch equations. This paper provides an analytical closed-formula of CEST contrast under steady state and transient conditions based on the eigenspace solution of the Bloch-McConnell equations for both of the MT and CEST effects as well as their interactions. In this paper, the CEST contrast has been modeled in two- and three-pool systems using measured (experimental- real data) and fitted data similar to the muscle tissue by considering interfering factors. The resulting error was characterized by an average of relative sum-square between three experimental data and fitted CEST contrast based on the proposed formulation lower than 4 percent. For further validation, these formulations were compared to the empirical formulation of the CEST effect based on a diamagnetic contrast agent introduced in the two-pool system. Using the proposed analytical expression for the CEST contrast, we optimized critical parameters such as concentration contrast agent, chemical exchange rate and characteristics of the electromagnetic radio frequency pulse via amplitude and pulse width in the rectangular pulse.
Full-Text [PDF 4133 kb]   (565 Downloads)    
Type of Study: Research | Subject: Paper
Received: 2019/04/10 | Accepted: 2020/01/22 | Published: 2020/12/5 | ePublished: 2020/12/5

References
1. [1] P. Zijl, and N. Yadav, "Chemical exchange saturation transfer (CEST): what is in a name and what isn't?," Magnetic Resonance Imaging, vol. 65, no. 4, pp. 927-948, 2011. [DOI:10.1002/mrm.22761] [PMID] [PMCID]
2. [2] E. Vinogradov, A. Dean Sherry, and R. E. Lenkinski, "CEST: from basic principles to applications, challenges and opportunities," Journal of Magnetic Resonance, vol. 229, pp. 155-172, 2012. [DOI:10.1016/j.jmr.2012.11.024] [PMID] [PMCID]
3. [3] P. Zijl, W. W. Lam, J. Xu, L. Knutsson and G. J. StanisZ, "MagnetiZation Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum," Nuroimage, vol. 168, pp. 222-241, 2018. [DOI:10.1016/j.neuroimage.2017.04.045] [PMID] [PMCID]
4. [4] K. L. Desmond and G. J. StanisZ, "Understanding quantitative pulsed CEST in the presence of MT," Magnetic Resonance in Medicine, vol. 67, no. 4, pp. 979-990, 2012. [DOI:10.1002/mrm.23074] [PMID]
5. [5] J.S. Lee, R.R. Regatte, A. Jerschow "Isolating chemical exchange saturation transfer contrast from magnetiZation transfer asymmetry under two-frequency RF irradiation, '' J Magn Reson, vol. 215, pp. 56-63, 2011. [DOI:10.1016/j.jmr.2011.12.012] [PMID] [PMCID]
6. [6] M. Zaiss, and P. Bachert,"Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods," Phys. Med. Biol, vol. 58, no. 22, pp 221-269, 2013. [DOI:10.1088/0031-9155/58/22/R221] [PMID]
7. [7] M.R. ReZaeian, G.A. Hossien-Zadeh and H. Soltanian-Zadeh, "Numerical Solutions to the Bloch-McConnell Equations with Radio Frequency", in: Proceedings of the international society of Electrical Engineering, 20th Con-ference on Electrical Engineering, Tehran, Iran, 2012, pp. 1584-89. [DOI:10.1109/IranianCEE.2012.6292613]
8. [8] M.R. ReZaeian, G.A. Hossien-Zadeh, and H.Soltanian-Zadeh,"Simultaneously ptimiZing power and duration of RF pulse in the paraCEST MRI", Magnetic Resonance Imaging, vol. 34, no. 6, pp. 743-753, 2016. [DOI:10.1016/j.mri.2016.02.001] [PMID]
9. [9] P. Z. Sun, "Simultaneous determination of labile proton concentration and exchange rate utiliZing optimal RF power: radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRI," Journal of Magnetic Resonance, vol. 202, no. 2, pp. 155-161, 2010. [DOI:10.1016/j.jmr.2009.10.012] [PMID] [PMCID]
10. [10] P.Z. Sun, P.C.M. van Zijl and J. Zhou, "OptimiZation of the irradiation power in chemical exchange dependent saturation transfer experiments," J Magn Reson, vol. 175, no. 2, pp. 193-200, 2005. [DOI:10.1016/j.jmr.2005.04.005] [PMID]
11. [11] P. Z. Sun, T. Benner, A. Kumar, and A. G. Sorensen, "Investigation of optimiZing and translating pH‐sensitive pulsed‐chemical ex-change saturation transfer (CEST) imaging to a 3T clinical scanner," Magnetic Resonance in Medicine, vol. 60, no. 4, pp. 834-841, 2008. [DOI:10.1002/mrm.21714] [PMID] [PMCID]
12. [12] B. Schmitt, M. Zaiß, J. Zhou, and P. Bachert, "OptimiZation of pulse train presaturation for CEST imaging in clinical scanners," Magnetic Resonance in Medicine, vol. 65, no. 6, pp. 1620-1629, 2011. [DOI:10.1002/mrm.22750] [PMID]
13. [13] D. Woeessner, S. Zhang, M.E. Merritt and A.D. Sherry, "Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI," Magn. Reson.Med, vol. 53, no. 4, pp. 790-799, 2005. [DOI:10.1002/mrm.20408] [PMID]
14. [14] R.V. Mulkern and M. L. Williams, "The general solution to the Bloch equation with constant RF and relaxation terms: application to saturation and slice selection," Med Phys, vol. 20, no.1, pp. 5-13, 1993. [DOI:10.1118/1.597063] [PMID]
15. [15] S.A. Roell, W. Dreher and D. LeibfritZ, "A general solution of the standard magnetiZation transfer model," J Magn Reson, vol. 132, no. 1, pp. 96-101, 1998. [DOI:10.1006/jmre.1998.1393]
16. [16] P.K. Madhu and A. Kumar "Direct Cartesian- space solutions of generaliZed Bloch equations in the rotating frame," J Magn Reson A, vol. 114, no. 2, pp. 201-211, 1995. [DOI:10.1006/jmra.1995.1127]
17. [17] K.Murase and N.Tanki, "Numeric solution to the time-dependent Bloch equations revisited," Magnetic Resonance Imaging, vol. 12, no.5, pp. 1-6, 2010. [DOI:10.1016/j.mri.2010.07.003] [PMID]
18. [18] A.X. Li, R.H.E. Hudson, J.W. Barrett, C. K. Jones, S. H. Pasternak and R. Bartha, "Four-pool modeling of proton exchange processes in biological systems in the presence of MRI-paramagnetic chemical exchange saturation transfer (PARACEST) agents," Magn. Reson.Med, vol. 60, no. 5, pp. 1197-1206, 2008. [DOI:10.1002/mrm.21752] [PMID]
19. [19] M. Zaiss, Z. Zu, J. Xu, P. Schuenke, D. F. Gochberg, J. C. Gore, M. E. Ladd, and P. Bachert,"A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetiZation transfer," NMR in Biomed, vol. 28, no. 2, pp 217-230, 2014. [DOI:10.1002/nbm.3237] [PMID] [PMCID]
20. [20] S. Goerke, M. Zaiss, and P. Bachert, "CharacteriZation of creatine guanidium proton exchange by water-exchange (WEX) spectroscopy for absolute pH CEST imaging in vitro," NMR Biomed, vol. 27, no . 5, pp 507-518, 2014. [DOI:10.1002/nbm.3086] [PMID]
21. [21] S.A. Smith, J.A.D. Farrell, C.K Jones, D.S. Reich, P.A. Calabresi and P.C.M van Zijl, "Pulsed magnetiZation transfer imaging with body coil transmission at 3 Tesla: feasibility and application," Magn. Reson.Med, vol. 56, no. 4, pp. 866-875, 2006. [DOI:10.1002/mrm.21035] [PMID]
22. [22] W. T. Dixon, J. Ren, A. J. Lubag, J. Ratnakar,E. Vinogradov, I. Hancu, R. E. Lenkinski and A. D. Sherry, "A concentration-independent method to measure exchange rates in PARACEST agents," Magnetic Resonance in Medicine, vol. 63, no. 3, pp. 625-632, 2010. [DOI:10.1002/mrm.22242] [PMID] [PMCID]
23. [23] T. Jin and S. G. Kim, "Approximated analytical characteriZation of the steady-state chemical exchange saturation transfer (CEST) signals", Magnetic Resonance in Medicine, vol. 82, no. 5, pp.1876-1889, 2019. [DOI:10.1002/mrm.27864] [PMID] [PMCID]
24. [24] J. Kim, Y. Wu, Y. Gue, H. Zheng, and P. Z. Sun, "A review of optimiZation and quantification techniques for chemical exchange saturation transfer (CEST) MRI toward sensitive in vivo imaging," Contrast Media Mol Imaging, vol. 10, no.3, pp.163-178, 2015. [DOI:10.1002/cmmi.1628] [PMID] [PMCID]

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2015 All Rights Reserved | Signal and Data Processing